RayPlex Pertuzumab (Perjeta®) Drug Antibody Assay

The RayPlex Pertuzumab (Perjeta®) DA kit is a cytometric bead assay to quantitatively measure Pertuzumab (Perjeta®) antibodies by flow cytometry. The assay has been optimized for serum and plasma.
As low as $598.00
In stock
Only %1 left
Catalog #:
DA-Pertuzumab
-
+

Product Description

Specifications

Size 48 tests, 96 tests, 192 tests, 480 tests
Species Human
Protein Name / Synonyms Pertuzumab (Perjeta®), ?HER2
Compatible Sample Types Plasma, Serum
Solid Support Fluorescent Microbeads
Method Of Detection Flow Cytometry
Research Area Antibody Drug Development, Drug Antibody (DA) Detection
Estimated Lead Time 4 weeks
Shipping Type Blue ice
Storage 4°C
Amazon Gift Cards!

$5 Amazon gift card in every kit box purchased.

Introduction

Therapeutic agents, including antibodies and proteins, have been widely used to treat cancer, inflammation, allergy, and other diseases. Monitoring drug antibody (DA) level has been critical to determine the optimal dose for clinical treatment. Especially knowing the kinetics of DA level is important for evaluation of DA efficacy and safety. Testing DA level combined with testing anti-drug antibody (ADA) level can help determine whether ADA in individuals affect DA efficacy. The RayPlex® DA Bead Assay is a sandwich- and bead-based fully quantitative assay for the detection of one or multiple DAs using small sample volumes. It features high sensitivity, high stability, and high throughput with the reliable flow cytometry methodology. RayPlex® DA Bead Assay requires no dedicated instrument and can be performed on most standard flow cytometers equipped with blue (PE) and red (APC) lasers.

RayPlex® DA Assays are tested as antibody bridge model. First ADAs are immobilized onto microbeads. After incubating the sample with the microbeads, DAs are captured on the bead surface, and biotinylated same ADAs are added, followed by PE-conjugated streptavidin. This enables protein detection via the PE-streptavidin-biotin-antibody complex. In a multiplex setting, individual DAs are identified by their specific bead populations, while the level of PE fluorescence reflects the amount of DA that has been captured to the beads. The DA level can be assessed (i.e., quantified) by comparing the PE signal to a standard curve generated from DA standards at known concentrations.

Application Notes

Kit Components
  • ADA Conjugated-RayPlex® Beads
  • 1X Assay Diluent
  • 20X Wash Buffer
  • RayBio® Serum Diluent
  • Liquid Standard
  • Biotinylated ADA
  • 10X Streptavidin-PE
  • Flow Cytometer Setup Beads
  • V-bottom 96-well Microplate
  • Filter 96-well Microplate
Other Materials Required
  • Orbital 96-well plate shaker (with ability to reach 1000 rpm)
  • Flow cytometer with blue and red lasers capable of measuring phycoerythrin (PE) and allophycocyanin (APC) channels
  • Aluminum foil or 96-well Plate Aluminum Sealers
  • Distilled water
  • 1.5 ml polypropylene microcentrifuge tubes or similar
  • Microcentrifuge
  • Recommended: Vacuum manifold compatible with a 96-well microplate if using the Filter 96-Well Microplate (Item 10)
  • Optional: 96-well round bottom plate (to prepare samples)
  • Optional: High throughput sampler (HTS) for 96-well plate reading

Don't have a compatible flow cytometer? RayBiotech provides full testing services for RayPlex bead assays. Get a quote!

Storage/Stability

Upon receipt, all components should be stored at 4°C. Use reagents immediately after preparation. Additional vials of the Liquid Standard (Item 5) can be purchased separately. If stored at the proper temperature, the kit will retain complete activity for at least 6 months.
Write Your Own Review
Your Rating
Submit a review for this product on Biocompare.com to earn an entry into a monthly raffle for one of five $100 Amazon gift cards!

Ask a Question

Display name:
Your location:*
This field is for validation purposes and should be left unchanged.