NAD+/NADH Assay Kit (Colorimetric)

The RayBiotech NAD+/NADH Assay Kit provides a simple, reproducible, and sensitive tool of measuring NAD+/NADH concentration in cell lysates and other biological liquid samples.
As low as $449.00
In stock
Only %1 left
Catalog #:
MA-NAD
-
+

Product Description

Specifications

Size 1 Plate Kit, 2 Plate Kit, 5 Plate Kit
Quantitative/Semi-Quantitative Quantitative
Compatible Sample Types Plasma, Serum, Cell Lysates
Solid Support 96-well Microplate
Method Of Detection Colorimetric
Research Area Metabolism
Sensitivity 5.8 nM
Detection Range 5.8 nM - 1000 nM
Estimated Lead Time 1-2 business days
Shipping Type Blue ice
Storage -20°C
Amazon Gift Cards!

$5 Amazon gift card in every kit box purchased.

Introduction

NAD is a complex organic molecule found in all living cells. It exists in two forms: oxidized (NAD+) and reduced (NADH). In cells, NAD+ acts as an electron acceptor, becoming reduced to NADH by accepting electrons from other molecules. In addition to electron transfer, NAD+ and NADH are also used as enzyme substrates to add or remove posttranslational modifications from proteins, such as in the process of ADP ribosylation. Quantitative determination of NAD+/NADH has applications in research related to energy transformation and redox state of cells or tissues.

NAD+/NADH Assay Kit provides a simple, reproducible, and sensitive tool of measuring NAD+/NADH concentration in cell lysates and other biological liquid samples. The assay is based on an enzymatic cycling reaction. NAD+ is reduced to NADH by alcohol dehydrogenase during the oxidation of ethanol to acetaldehyde. Then NADH reacts with a colorimetric probe that produces a colored product which can be measured at 450 nm. The intensity of the product color is proportional to the NAD+ and NADH within a sample.

Kit Components

ComponentSize / Description
MicroplateA 96-well (12 strips x 8 wells) plate
Assay Buffer15 mL
NADH Standard1 vial (Lyophilized)
NAD Cycling Enzyme Mix1 vial (Lyophilized)
Colorimetric Probe1 vial (Lyophilized)
Ethanol Solution1 vial (250 µL)
NAD+ Extraction Solution10 mL
NAD+ Neutralization Solution10 mL
NADH Extraction Solution10 mL
NADH Neutralization Solution10 mL

Additional Materials Required

  • Microplate reader capable of measuring absorbance at 450 nm
  • Precision pipettes to deliver 2 μL to 1 mL volumes
  • Tubes to prepare sample dilutions
  • Ultrapure water
  • 15 mL conical tubes

Assay Procedure Summary

  1. Add 10 µL of the diluted NADH Standards or NAD+, NADH samples to the 96-well microtiter plate.
  2. Initiate the reaction by adding 90 µL Working Solution to each well. Carefully shake the plate for a few seconds to mix.
  3. Incubate the plate for 30 minutes at room temperature with gentle mixing in the dark.
  4. Measure the absorbance at 450nm using a plate reader.

Storage/Stability

The entire kit should be stored below -20°C for up to 6 months from the date of shipment.
Write Your Own Review
Your Rating
Submit a review for this product on Biocompare.com to earn an entry into a monthly raffle for one of five $100 Amazon gift cards!

Ask a Question

Display name:
Your location:*
This field is for validation purposes and should be left unchanged.