Phospho-AKT (S473) and Total Akt ELISA Kit

Semi-quantitatively measures phophorylated Akt (Ser473) in lysate samples
As low as $567.00
In stock
Only %1 left
Catalog #:
PEL-AKT-S473-T
-
+

Product Description

Specifications

Size 1 Plate Kit, 2 Plate Kit, 5 Plate Kit
Species Human, Mouse, Rat
Accession Number P31749
Gene Id 391
Gene Symbols AKT1|PKB|RAC
Protein Name / Synonyms RAC-alpha serine/threonine-protein kinase (EC 2.7.11.1) (Protein kinase B) (PKB) (Protein kinase B alpha) (PKB alpha) (Proto-oncogene c-Akt) (RAC-PK-alpha)
Quantitative/Semi-Quantitative Semi-Quantitative
Specificity The antibody pair provided in this kit recognizes human, mouse and rat Phospho-Akt (pSer473) + pan Akt.
Compatible Sample Types Tissue Lysates, Cell Lysates
Solid Support 96-well Microplate
Method Of Detection Colorimetric
Design Principle Sandwich-based
Research Area Post-Translational Modifications, Phosphorylation, mTOR Signaling, PI3K-AKT Signaling, Insulin Signaling
Estimated Lead Time 1-2 business days
Shipping Type Blue ice
Storage -20°C

Risk-Free Guarantee

We offer a 100% guarantee on all ELISA kits and membrane cytokine arrays.

Learn More
Amazon Gift Cards!

$5 Amazon gift card in every kit box purchased.

Product Features

  • Simultaneously measure Phosphorylated protein and pan protein in one experiment (for normalization purpose)
  • Screen numerous different cell lysates without performing a Western Blot analysis
  • Minimal hands-on time, convenient, and non-radioactive material

Application Notes

Kit Components
  • Pre-Coated 96-well Strip Microplate
  • Wash Buffer
  • Anti-Phospho Antibody
  • Anti-Pan Antibody
  • HRP-Conjugated Secondary Antibody
  • Streptavidin-Conjugated HRP
  • Assay Diluent
  • TMB One-Step Substrate
  • Stop Solution
  • Lysis Buffer
  • Positive Control Sample
Other Materials Required
  • Distilled or deionized water
  • 100 ml and 1 liter graduated cylinders
  • Tubes to prepare sample dilutions
  • Protease and Phosphatase inhibitors
  • Precision pipettes to deliver 2 µl to 1 ml volumes
  • Adjustable 1-25 ml pipettes for reagent preparation
  • Benchtop rocker or shaker
  • Microplate reader capable of measuring absorbance at 450 nm
Protocol Outline
  1. Prepare all reagents and samples as instructed in the manual.
  2. Add 100 µl of sample or positive control to each well.
  3. Incubate 2.5 h at RT or O/N at 4 °C.
  4. Add 100 µl of prepared primary antibody to each well.
  5. Incubate 1 h at RT.
  6. Add 100 µl of prepared 1X HRP-Streptavidin to each well.
  7. Incubate 1 h at RT.
  8. Add 100 µl of TMB One-Step Substrate Reagent to each well.
  9. Incubate 30 min at RT.
  10. Add 50 µl of Stop Solution to each well.
  11. Read at 450 nm immediately.

Storage/Stability

Upon receipt, the kit should be stored at -20 °C. Please use within 6 months from the date of shipment. After initial use, Wash Buffer Concentrate (Item B), Assay Diluent (Item E), TMB One-Step Substrate Reagent (Item H), HRP-Streptavidin (Item G), Stop Solution (Item I) and Cell Lysate Buffer (Item J) should be stored at 4 °C to avoid repeated freeze-thaw cycles. Return unused wells to the pouch containing desiccant pack, reseal along entire edge and store at -20 °C. Reconstituted Positive Control (Item K) should be stored at -70 °C.
Wang N., Rayes R., Elahi S., et al. The IGF-Trap: Novel Inhibitor of Carcinoma Growth and Metastasis. Mol Cancer Ther. 2015 Apr;14(4):982-93. doi: 10.1158/1535-7163.MCT-14-0751.
Species:
Mouse
Sample Type:
Cell Lysate (Metastatic colon carcinoma cell lines MC-38 and Lewis lung carcinoma H-59 cells.)
  1. Great product
    Rating
    100%
    The product worked as advertised. Will plan to use again

    Review by

    from Bronx High School of Science,

    on

  2. Great product
    Rating
    100%
    This ELISA worked exactly as described. Thanks!

    Review by

    from Columbia,

    on

Write Your Own Review
Your Rating
Submit a review for this product on Biocompare.com to earn an entry into a monthly raffle for one of five $100 Amazon gift cards!

Ask a Question

Display name:
Your location:*
This field is for validation purposes and should be left unchanged.